web: www.vcit.ca blog: www.vcit.ca/wordpress 1363-97539-692360 Best Answer Back to top Eric Lominac Members #5 Eric Lominac 10 posts Posted 18 December 2009 - 07:58 PM I realized that I hadn't ever Failed to Set Event Logging message on Windows 7 Started by Mark Mears , 09 October 2012 - 04:22 PM Login to Reply 4 replies to this topic Mark Mears Members This web site is © 2007-2016 by J House Consulting | XML Sitemap | HTML Sitemap | Plugins Used WordPress Admin ERROR The requested URL could not be retrieved The following web: www.vcit.ca blog: www.vcit.ca/wordpress Go to the full post

Eric Lominac Members #1 Eric Lominac 10 posts Posted 26 December 2007 - 09:07 PM We have two farms in my http://txtbl.com/wfcrun32-error/wfcrun32-error-failed-event-logging.html

Thanks to above. 1367-258500-1463311 Back to top Report abuse Back to Presentation Server 4.5 - General Reply to quoted posts Clear Citrix ©1999-2016 Citrix Systems, Inc. All rights reserved. I have encounter this after installing the msi using system context in windows7. The issue was the AppData redirection GPO wasn't running for everyone on the first logon, so the path in appsrv.ini was set to C:\Docs..., but then next time they logged in http://support.citrix.com/article/CTX118553

Wfcrun32 Error Unable To Launch Application

When the CitrixReceiver file executes it extracts the individual MSI files and runs them in the order specified above. - I did not have the problem when executing in the context Uninstalling and reinstalling does not correct the issue. I was running Windows 7 as the low-rights user and using an elevated Command Prompt to perform the installation. http://support.citrix.com/article/CTX126950 http://forums.citrix.com/thread.jspa?threadID=88181&start=0&tstart=0 Command Line switches from Citrix http://support.citrix.com/proddocs/topic/online-plugin-120-windows/ica-configure-command-line.html Answered 08/26/2011 by: mreusguy Please log in to comment Please log in to comment 0 I am new to this forums........

If you're writing your own script, then you would use %AppData%. Several functions may not work. This can be a large task, especially on an enterprise network, however, Group Policy Preferences can help. Wfcrun32.exe Application Error Citrix Like it's using %userprofile%\Application Data which, for us, doesn't exist.Does anyone have a solution to this?

Registry key to suppress the UAC HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Policies\System EnableLUA = 0 (REG_DWORD) ConsentPromptBehaviorAdmin = 0 (REG_DWORD) Registry key to enable the UAC HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Policies\System EnableLUA = 1 (REG_DWORD) ConsentPromptBehaviorAdmin = 5 (REG_DWORD) It Citrix ne peut être tenu responsable des incohérences, des erreurs ou des dommages causés par l'utilisation des articles traduits de facon automatique. You don't say if this occurs when you manually install the software, or just when installing in a system context. Please re-enable javascript to access full functionality.

Error gone. Appsrv.ini Location Windows 7 These comments are my own observations. - Command line parameters for the MSI files was extracted from the installation log created by running CitrixReceiver.exe and copying and examining the log files Citrix ist nicht verantwortlich für Inkonsistenzen, Fehler oder Schäden infolge der Verwendung automatisch übersetzter Artikel. Solution Immediately after the installation of the Citrix Client delete the APPSRV.INI file from the default user’s \ICAClient directory.

Wfcrun32.exe Application Error

Windows 7 successfully prevented the low-rights access to the file and this was what resulted in the error (Failed to Set Event Logging) being displayed. http://discussions.citrix.com/topic/287830-wfcrun32-error-failed-to-set-event-logging-on-one-citrix-server-only/ Currently users who receive this error do not have an appserv.ini file in their profiles (either on the server, in the roaming profile directory, or even in their home drives) We Wfcrun32 Error Unable To Launch Application and delete or rename.Let your user test again. Wfcrun32.exe Citrix Download Related Categories: Citrix, Client Tags: Citrix, error, wfcrun32, XenApp Comments (2) Trackbacks (0) Leave a comment Trackback Marco H. 26th June, 2013 at 13:21 Reply %AppDataDir% doesn't exist I think it

Toggle navigation Software Tips Questions Blogs Links Communities Questions & Answers wfcrun32 ERROR-failed to set Event Logging wfcrun32 ERROR-failed to set Event Logging gibo How helpful is this to you? http://txtbl.com/wfcrun32-error/wfcrun32-error-failed-to-set-event-logging-install.html It should be as follows: "C:\Program Files\Citrix\ICA Client\wfica32.exe" "%1" I'm wondering if perhaps your problem clients associations are set to wfcrun32.exe instead. If you ran a manual installation, you can copy the appsrv.ini file from the real user profile into the Default User profile, and edit the path so that logging is set Problem Cause The error occurs if the user’s profile was moved after the XenApp plugin was installed. Wfcrun32 Citrix

And the fact that the system context may not be able to access some path. I am trying to develop a package for enterprise deployment. I cannot find any error/warning messages in it. have a peek at these guys Answered 07/07/2010 by: krulik Please log in to comment Please log in to comment 0 I forgot to say that error appears only if UAC is enabled.

It's difficult to catch this because the system will allow you to successfully install the XenDesktop Web-Plugin without throwing errors.Jaime Porras 1363-97539-1559577 Back to top Report abuse Back to Windows (Online Citrix Receiver Windows 10 Is there a LogFileWin32 path specified in it? Also, try granting the locals users group on an affected workstation modify and write perms to the folder "C:\Program Files\Citrix\ICA Client" Cheers, Alan Osborne President VCIT Consulting - providing Small and

Sign up today to participate, stay informed, earn points and establish a reputation for yourself!

Our users will be logged into their workstations during the deployment and the installation needs to require NO interaction and be completely silent.What I've tried:- Used command line switches on the I found a way to do it. 1305-314627-1680036 Back to top Stefan Brutscher Members #3 Stefan Brutscher 19 posts Posted 16 October 2012 - 01:14 PM How do you solve your All Rights Reserved Privacy & Terms Jump to content Citrix Citrix Discussions Log In Citrix.com Knowledge Center Product Documentation Communities Blogs All CategoriesAppDNAArchived Products (includes End...Citrix CloudCitrix Connector for System CenterCitrix You can't supply a variable like %username%, because the ini file mechanism does not recognise it.

Similarly you can't use %temp%.You also can't edit the appsrv,ini file until it exists, and when it exists the user has received the error. Setting DONOTSTARTCC=1 will also prevent the following error "WFCRUN32 Error - Failed to set Event Logging" Here are the articles about this error. Today, I got the WFCRUN32 error on logging on, and my LogFileWin32 path has changed. http://txtbl.com/wfcrun32-error/wfcrun32-error-failed-to-set-event-logging-fix.html stornieren Citrix技术支持 自动翻译 本文是通过自动翻译系统翻译的,未经人工审查。Citrix 提供自动翻译以提高对支持内容的访问,但自动翻译的文章可能包含错误。对于因使用自动翻译的文章导致出现的不一致、错误或损害,Citrix 不承担任何责任。 取消 Citrix技術支持 自動翻譯 這篇文章被翻譯由一個自動翻譯系統,並沒有受到人們的審查。 Citrix提供自動翻譯,增加獲得支持的內容;但是,自動翻譯的文章可能可以包含錯誤。思傑不負責不一致,錯誤或損壞因使用自動翻譯的文章的結果。 取消 Citrixのサポート 機械翻訳 この技術情報資料は、機械翻訳システムによって翻訳されたもので翻訳者によるレビューは受けていません。Citrixでは、サポートコンテンツへアクセスする機会を増やすため、機械翻訳を提供しています。しかしながら、機械翻訳の品質は翻訳者による翻訳ほど十分ではありません。誤訳や、文法、言葉使い、その他、たとえば日本語を母国語としない方が日本語を話すときに間違えるようなミスを含んでいる可能性があります。機械翻訳の品質、および技術情報資料の内容の誤訳やお客様が技術情報資料を利用されたことによって生じた直接または間接的な問題や損害については、いかなる責任も負わないものとします。 キャンセル Поддержка Citrix Traducao automática Эта статья была переведена автоматической системой перевода и не был рассмотрен

This Blog has an additional step that was taken on a virtual desktop. CANCEL Soutien Citrix Traduction automatique Cet article a été traduit à l'aide d'un système de traduction automatique et n'a pas été relu. However the logging path remains the same - a path to the Default User profile.This can't work. CTX118553's fix didn't work for me either.

Automatisch übersetzte Artikel können jedoch Fehler enthalten. Several functions may not work. The file can be located at:C:\Documents and Settings\%user%\Application Data\ICAClient\APPSRV.INIIf you are using a default user profile, which is inherited to all domain users, then this path will contain the incorrect username They can click "OK" and continue without incident, but find the error off-putting.

Several functions may not work. A new appsrv.ini file is created from the Default User copy, with the wrong path, and the error message occurs.Steps to fix:1) Run the automated setup of the web client2) Delete Users on a published desktop sometimes launch an app that runs from another server. What if the log file path was not located in the user profile?

At a particular point in the installation the low-rights user account tries to access the APPSRV.INI file located in the %ProgramFiles (x86)% folder requesting write access which it does not have. The log file path in the Users Appsrv.ini is incorrect. Either update the file or delete the folder and it will recreate what it needs. The system returned: (22) Invalid argument The remote host or network may be down.

During the next logon that folder is being recreated and the message doesn't show up again. 1367-258500-1432728 Back to top Mark Prigg Members #8 Mark Prigg 1,177 posts Posted 28 January Go to the Local Client Machine (logon as admin) search for Appsrv.ini as well ... CANCELLARE Citrix Support Automatische Übersetzung Dieser Artikel wurde mit einem automatischen Übersetzungssystem übersetzt und nicht von Personen überprüft.