Check cable and retest. Replace Drive 550 Abort Cmd Abort Command. An onboard defect counter has determined the drive has too many errors and should be replaced. An interrupt command to perform a specific task failed to complete. http://txtbl.com/western-digital/western-digital-hard-drive-error-codes.html

Report back. This error is most likely an internal malfunction of the drive and not related to the condition of the cables etc. Replace. If the error repeats, replace the drive.

Wd 08-unable To Repair Bad Sectors

Replace Drive 163 Unknown Error Queued command timed out. Data sent between the host computer and the drive has been corrupted. Please re-test the drive with Data Lifeguard. SCT Data Table supported.

One is that the stock of Good Spares is getting low, so continuing without remedial action risks getting to the point that there are no more Good Spares to use, and The drive has not responded back in the time allotted. Please contact the system vendor for the above-mentioned information. Western Digital Quick Drive Test Failed The Quick tests check several easy things, and one of those is to check the SMART data stored on the controller board of the HDD unit itself.

So the problem wasnt the SATA cable, it was something to do with the old drive being connected. Western Digital Test Error Code 08- A number of ECC errors (between 2 through 9) have been detected. Re-Test Drive 556 SERVO 1 SERVO is data on track location. http://support.wdc.com/knowledgebase/answer.aspx?ID=940 So my theory was at that point, it was a dodgy cable!

Please ensure that you are not loading any other DOS level files from the floppy prior to running diagnostic utility. Status Code 07 Failure Checkpoint 97 This may be an anomaly. That board runs tests on the HDD all the time in the background, and writes any error messages to its own CMOS for later retrieval. (By the way, Enabling SMART Reporting If all goes well, by the time the Zero Fill is finished, there will be NO "Bad Sectors" in use at all.

Western Digital Test Error Code 08-

Replace your cable and retest. http://www.tomshardware.com/forum/282166-32-data-diagnostics-chkdsk-conflict The drive has failed and must be replaced. Wd 08-unable To Repair Bad Sectors Replace the drive if the error repeats. Smart Offline Immediately Command Error On Drive 1 That may well be an indication that this disk is progressing from questionable reliability to not reliable at all, but maybe not.

Auto Offline data collection on/off support. check my blog SERVO is data on track location. Replace the drive if the error repeats. I'm not worried about those if they're still there, because apparently they haven't caused any problems for the last year and a half. Read Smart Attribute Command Error On Drive 2

If Selective self-test is pending on power-up, resume after 0 minute delay. Sorry to say this, but maybe that's why this used HDD was being sold on eBay - the previous owner has replaced one with SMART errors while it was still functional.Running Retest after checking the connections. http://txtbl.com/western-digital/western-digital-hard-drive-error-checker.html If the drive is recognized there, than something is likely wrong with either the power supply, or the data port (or BUS) that the drive is being connected to.

Error: (10/04/2014 09:53:23 AM) (Source: Microsoft Antimalware) (User: ) Description: The support for your operating system has expired. Western Digital Bad Sector Repair CHKDSK reports unrepairable parts WD 3TB HDD Storage New Build HDD Problems 2tb storage Hdd and bios Trouble adding storage HDD's to new SSD installation. Here is the output from Minitoolbox.

They can be compared to the 2/27/13 test earlier in the thread.

It is also possible to see this error on defective Western Digital drives. Re-Test Drive 107 Check Sum Error Accumulated test data on the drives is corrupted. Selective Self-test supported. Too Many Bad Sectors Detected Replace the drive if the error repeats.

If ECC occurs, use Data Lifeguard for additional error correction. Replace Drive 216 10+ IDNF Errors Identified Data Not Found (IDNF) 10+. Replace your cable and retest the drive. http://txtbl.com/western-digital/western-digital-hard-drive-error-0225.html Try reinstalling the Data Lifeguard Diagnostics for Windows utility.